Elgar CW-P Series Specifications
Operation Manual 1-3
PHASE
Range -359 to +359 degrees
Positive phase indicates time lag from reference
Accuracy Within 100 microseconds of equivalent angle
Resolution 1 degree
1.2 Measurement
VOLTAGE
Range 0 to 270 VRMS; VOption: 0 to 310 VRMS
Accuracy ±0.1% of range <100 Hz; ±0.2% of range ≥100Hz;
at >5 VRMS output; measured at point of remote sense
H-Option: ±0.3% of range >500 Hz
Resolution 0.1 VRMS
CURRENT*
Range
CW 801P 0 to 6.0 ARMS
CW 1251P 0 to 9.4 ARMS
CW 2501P 0 to 18.6 ARMS
Accuracy ±0.5% of range typical; for linear loads and
>0.12 ARMS for CW 801P, >0.19 ARMS for CW 1251P,
>0.37 ARMS for CW 2501P
H–Option/VOption: ±0.75% of range and 500 Hz;
±1.0% of range and >500 Hz
Resolution 0.01 ARMS
PEAK INSTANTANEOUS CURRENT*
Range
CW 801P 0 to 25A
CW 1251P 0 to 35A
CW 2501P 0 to 70A
Accuracy ±2% of range typical; at >2% current range
Resolution 0.1A